Before you closeQuestions, budget and conditions
Questions to ask the seller
- How old are the roof shingles, and is there any warranty or paperwork? Have there ever been roof or attic leaks, a fire, or animals in the attic?
- How old are the furnace and the central air conditioner, and are there service records? When was the humidifier last serviced?
- The listing shows the electric water heater is under a rental contract. Ask for the company, the monthly cost and the buy-out or return terms, and whether they will replace this 2005 tank before or after closing.
- The listing gives the roof and foundation as "unknown" and provides no Seller Property Information Statement. Ask the seller to answer the questions in this list in writing.
- The listing says there is no central vacuum, but an Electrolux central vacuum unit is in the utility room. Ask whether it works and whether it is included.
- Has water ever come into the basement, especially in the closet under the stairs or in the cold room?
- Were permits taken out for the basement kitchen and bathroom? If you plan to rent the basement as a separate unit, check its status with the City of Toronto, because a rental unit has fire-separation, exit and alarm requirements that this inspection does not assess.
- Was the house ever heated with oil, and if so, was the tank removed and documented? We saw no sign of a tank. The pipe on the driveway-side wall that we checked was an active exhaust, not an oil vent.
- What is the capped pipe in the floor of the small upper room, and is it disconnected?
- Has any electrical work been done under an ESA permit? Is the electrical service owned by the house or shared in any way?
Items to plan and budget for
Get contractor quotes; this report does not estimate costs.
Furnace replacement
Age unconfirmed, possibly about 20 years. Confirm it from the nameplate, service it now, and plan for replacement.
Water heater
21 years old and rented (per the listing). Ask the rental company to replace it, or budget for a buy-out and replacement.
Central air conditioner
Appears to be an R-22 system (refrigerant not confirmed); R-22 has been phased out. A refrigerant leak or major failure usually means replacing the system.
Electrical updates
GFCI protection, receptacle wiring corrections, cleanup at the panel, and possibly a larger panel or service.
Attic air sealing and insulation
Remove the damaged material, air-seal, then insulate to current levels.
Chimney repointing and crown
Repoint the mortar, repair the crown, and add a cap to the vent.
Basement wall moisture
Correct the drainage first; waterproofing work if the dampness continues.
Garage
Door safety sensors, the wood door and trim, block wall repairs and wiring.
Front steps and railings
Concrete repairs and rust treatment, or replacement of the railings.
Inspection conditions
Weather
Clear, with morning fog
Outdoor temperature
7.8 °C
Indoor temperature
22 °C
Occupancy
Vacant (furnished)
In attendance
Buyer's agent
Property type
Detached 1½-storey brick house with finished basement and detached garage
Approximate age
Not confirmed. Construction style suggests the late 1940s to 1950s.
Floor area
About 212 m² in total (basement 91 m², main floor 75 m², upper floor 46 m²), from the floor plan
Utilities
Water, power and gas on
Roof method
Drone (aerial photographs) plus ground level
Scope, standards and limitations
Scope. This was a visual, non-invasive inspection of the readily accessible systems and components of the home, done to give you a general understanding of its condition on the day of the inspection. It is not technically exhaustive and does not predict future conditions.
Standards. The inspection followed the InterNACHI Home Inspection Standards of Practice. A copy is available on request.
Limitations. Areas that were concealed, inaccessible, unsafe, or blocked by belongings or finishes could not be inspected. Systems were run only with their normal controls. Conditions can change after the inspection date. Where this report recommends further evaluation, have a qualified contractor do it before closing where possible.
Use of this report. This report was prepared for the client named on the cover, under the inspection agreement signed before the inspection, and is for the client's use only. It is not a warranty, guarantee or insurance policy. Anyone else who receives a copy should not rely on it and should arrange their own inspection.
Limitations specific to this inspection
- Stored belongings blocked parts of the garage walls, floor and ceiling, the inside of the upper storage room closet, and the closet in main-floor bedroom 1. Areas behind furniture were not checked.
- The basement walls and ceilings are mostly finished, which hides the foundation, framing, wiring and plumbing.
- The central air conditioner was not run because of the low outdoor temperature.
- The roof was viewed by drone and from the ground; it was not walked.
- The attic was inspected from the two knee-wall access openings but not entered, because the inspector judged it unsafe (no walkway over open joists, loose boards and debris, tight headroom). Areas out of view from the openings were not inspected.
- A pin-type moisture meter was not permitted. Moisture readings were taken with a pinless meter, which compares one area with another and does not give exact moisture content.
- We did not test for mould, asbestos, lead, radon or other environmental hazards, check the building against code, or estimate repair costs.